#----------------------------------------------------------------------- # An Advanced Virgo Plus input file for Finesse 3 # # Variable for the detection part of the interferometer # Mode-matching Telescope parameters variable MMT_L_f -3.596 variable MMT_M1_R 1.0 variable MMT_M1_T 0.0 variable MMT_M1_Rc 1.44 variable MMT_M2_R 1.0 variable MMT_M2_T 0.0 variable MMT_M2_Rc 0.09 variable MMT_L1_f 0.582 variable MMT_L2_f -0.881 variable length_MMT_1 0.6 units='m' variable length_MMT_2 0.765 units='m' variable length_MMT_3 0.5 units='m' variable length_MMT_4 0.12 units='m' # Output Mode Cleaner variable OMC_1_1_R 0.99715 variable OMC_1_1_T 0.00285 variable OMC_1_1_alpha 6.0 variable OMC_1_2_R 0.99715 variable OMC_1_2_T 0.00285 variable OMC_1_2_alpha 6.0 variable OMC_1_3_T 1.1e-6 variable OMC_1_3_L 0.0 variable OMC_1_3_alpha 6.0 variable OMC_1_3_Rc 1.7 variable OMC_1_4_T 1.3e-6 variable OMC_1_4_L 6e-5 variable OMC_1_4_alpha 6.0 variable length_OMC_1_1 0.0613 units='m' variable length_OMC_1_2 0.0626 units='m' variable length_OMC_1_3 0.0613 units='m' variable length_OMC_1_4 0.0626 units='m' # Link between MMT & OMC variable length_MMT_OMC 0.99 units='m'