Interferometer or part-interferometer modeling files to study Virgo on finesse3 simulation software.
Find a file
2024-10-02 17:41:10 +02:00
.gitignore
00_variables.kat
01_arm_north.kat
01_arm_west.kat
01_detection.kat
01_laser_and_modulator.kat
01_recycling_cavity.kat
01_simple_variables.kat
02_B5_path.kat
05_attenuator.kat
05_link_length.kat
05_modulation.kat
05_tuning.kat
10_arm_north.kat
10_arm_west.kat
10_B2_attenuator.kat
10_B4_attenuator.kat
10_detection.kat
10_faraday_isolator.kat
10_laser_and_modulator.kat
10_recycling_cavity.kat
10_simple_beamsplitter.kat
10_simple_detection.kat
10_simple_laser.kat
10_simple_mirror.kat
15_B5_path.kat
20_link_faraday_isolator_recycling_cavity.kat
20_link_recycling_cavity_arms.kat
25_link_B5_noSDB1.kat
25_link_B5_SDB1.kat
25_link_faraday_isolator_B2_attenuator_noSIB2.kat
25_link_faraday_isolator_B2_attenuator_SIB2.kat
25_link_laser_and_modulator_faraday_isolator_noSIB1.kat
25_link_laser_and_modulator_faraday_isolator_SIB1.kat
25_link_recycling_cavity_B4_attenuator_noSPRB.kat
25_link_recycling_cavity_B4_attenuator_SPRB.kat
25_link_recycling_cavity_detection_noSDB1.kat
25_link_recycling_cavity_detection_SDB1.kat
25_link_simple_beamsplitter_detection.kat
25_link_simple_beamsplitter_mirror.kat
25_link_simple_laser_beamsplitter.kat
30_link_arm_north_SNEB.kat
30_link_arm_west_SWEB.kat
30_link_B5_SDB2.kat
50_cavities.kat
70_degree_of_freedom.kat
70_detectors.kat
75_B5_detectors.kat
99_after_variables.kat
README.md

Virgo model

Interferometer for Finesse 3. Can be used with the finesse-virgo package.

Katscript files are organized by priority number (first two number), which indicate the file loading order, the lowest at first.

Sections

Katscript files are organized in different types, which are values, optical setup, link, cavities definition, degree of freedom, detectors and after variables.

values

priority number from 00 to 09

Contains values used in the setup

optical setup

priority number from 10 to 19

Defined part of the optical setup (Laser, Mirror, etc.)

priority number from 20 to 49

Link together parts of the optical setup defined before

cavities

priority number from 50 to 69

Defines Finesse 3 cavity

degree of freedom

priority number from 70 to 89

Defines Finesse 3 degree of freedom

detectors

priority number from 70 to 89

Add Finesse 3 readout

after variables

priority number from 90 to 99

Defines variable which depends of components in the setup for preprocessing (finesse-virgo package for example)

Getting started

Code example to build a Virgo model with these scripts.

    virgo = Virgo(
        files_to_parse = [
            "00_variables.kat",
            "01_arm_north.kat",
            "01_arm_west.kat",
            "01_detection.kat",
            "01_laser_and_modulator.kat",
            "01_recycling_cavity.kat",
            "02_B5_path.kat",
            "05_attenuator.kat",
            "05_link_length.kat",
            "05_modulation.kat",
            "05_tuning.kat",
            "10_laser_and_modulator.kat",
            "10_faraday_isolator.kat",
            "10_recycling_cavity.kat",
            "10_arm_north.kat",
            "10_arm_west.kat",
            "10_detection.kat",
            "10_B2_attenuator.kat",
            "10_B4_attenuator.kat",
            "25_link_laser_and_modulator_faraday_isolator_noSIB1.kat",
            "20_link_faraday_isolator_recycling_cavity.kat",
            "25_link_faraday_isolator_B2_attenuator_noSIB2.kat",
            "20_link_recycling_cavity_arms.kat",
            "25_link_recycling_cavity_detection_noSDB1.kat",
            "25_link_recycling_cavity_B4_attenuator_noSPRB.kat",
            "30_link_arm_north_SNEB.kat",
            "50_cavities.kat",
            "70_detectors.kat",
            "70_degree_of_freedom.kat",
            "99_after_variables.kat",
        ],
    )

The advantage of this is the control we have over the interferometer simulation, and the readibility. Tracking change is also easier, variable definition being detached from setup configuration.